Data type
Setting
conditions
Waveform
1
data*
Numerical
calculation
results
Screen
image data
CAN
9
settings*
11
A2L file*
*1: Save waveform data in the binary format if you plan to load it with the instrument or the Logger
Utility. Some measurement setting conditions will be saved along with the waveform data. You
can also specify a range of data using the A/B cursors (partial save).
When you save waveform data after the scaling conversion in the binary format, raw data
(data prior to the scaling conversion) and scaling settings are recorded. Loading waveform
data allows waveforms after the scaling conversion to be displayed. You can review the pre-
conversion waveforms if you turn off the scaling setting.
*2: There is a limit on the number of rows that can be loaded at once when loading CSV data with
spreadsheet software.
*3: PNG format: An image format defined by the ISO/IEC 15948 international standard.
*4: Date folders ("year-month-day") will be automatically generated in the
number of files in a folder exceeds 1000, a new folder will be created.
Example: 20-01-10_1000
*5: For more information about filenames when saving data manually, see "11.7 Filenames" (p. 3 92).
*6: When a setting other than
[.TXT]. (p. 1 46)
*7: When
[Individual calc]
appended, as in
*8: Requires commercially available software that can load MDF data.
*9: File created on a PC (with the CAN Editor) and loaded by the instrument.
*10: Requires PC application (CAN Editor).
*11: File saved by the instrument and loaded by another company's PC application.
*12: Requires software that serves as the XCP master.
*13: Files containing data from wireless modules saved by the LR8450-01 cannot be loaded by the
LR8450 (which lacks wireless functionality).
The number of files
It is recommended to store fewer than 1000 files per folder.
You can save more than 1000 files in a single folder, but save times will increase with the file
count.
During automatic saving, a new folder will be created when the number of files in a folder
exceeds 1000.
Find Quality Products Online at:
Format
Folder name
Binary
CONFIG
Binary
4
DATA\(date)*
2
Text*
Example: 20-01-10
MDF
Text*
2
MEASUREMENT
3
PNG*
PICTURE
Binary
–
–
A2L
[Comma]
is selected, the string representing a calculation number will be
[MEAS0001_1.CSV]
GlobalTestSupply
www.
Saving
5
Filename
(Automatically
Auto.
numbered from 1)
CONF0001.SET
–
AUTO0001.MEM
WAVE0001.MEM
AUTO0001.CSV
WAVE0001.CSV
6
*
AUTO0001.MF4
AUTO0001.CSV
MEAS0001.CSV
*
7
SCR00001.PNG
–
3
*
****.CES
–
LR8450S0001.A2L
–
is selected under [Delimiter], the extension will be set to
and [MEAS0001_2.CSV].
: Yes; –: No
Loading
On the
On a
Manual
instrument
computer
–
13
*
–
–
*
–
–
–
*
–
*
[DATA]
folder. When the
.com
sales@GlobalTestSupply.com
8
10
12
Need help?
Do you have a question about the MEMORY HiLOGGER LR8450 and is the answer not in the manual?