Example: If set to
Example: If set to
Under
[File
Saved files will be segmented based on the set period of time.
Disable
Enable
Timed
(When
[File splitting]
Under
[Split
Day
(0
to 30), hour
(When
[File splitting]
Under
[Reference time]
Hour
(0
Under
[Split
1
min,
2
When measurement starts, the following message will be displayed until the recording interval is
synchronized with the reference time:
4
Under
[Format]
OFF
Text
Under
[File
Single file
Individual calc
Under
[Time split
The setting is the same as the
See "Configuring numerical calculations" (p.  1 94).
Find Quality Products Online at:
[1 week]
When measurement started on Sunday, December 29, 2019, the system will regard Monday,
December 23, 2019 as the beginning of the week.
The 19-12-23 folder will automatically be created.
[1 month]
When measurement started on December 29, 2019, the system will regard December 1, 2019 as
the beginning of the month.
The 19-12-01 folder will automatically be created.
splitting], select the segmentation method (as necessary).
Creates one waveform file for each measurement. However, files will be segmented
automatically if the file size exceeds 1 GB.
Segments files by the time specified in
when saving waveform data.
Under
[Split
time], set the time by which to segment files. However, files will be
segmented automatically if the file size exceeds 1 GB, even if the split time has not yet
been reached.
Before files are saved, the segment time of the first file will automatically be adjusted
so that data is segmented at regular intervals
time]. (Only the first file will become shorter than the
The following message will be displayed at the start of recording until the recording
interval is synchronized relative to the reference time, at which point the instrument will
enter the measurement start wait state:
is set to [Enable])
time], set the time by which to segment files.
(0
to 23), min.
(0
to 59)
is set to [Timed])
set the time to use as the reference when segmenting files.
to 23), min.
(0
to 59)
time], set the interval at which to segment files.
min,
5
min,
10 min
,
15
min,
in the
[Numerical calculation results]
Does not perform auto-save operation.
Saves data in text format.
splitting], select whether to segment saved files (as necessary).
Saves all numerical calculation results in one file.
Creates files segmented by calculation item, in addition to the file containing all of the
calculations together. A calculation number is appended to such folders.
Example: The filename for calculation No. 5 will be AUTO0001_05.CSV
calculation], select whether to segment the numerical calculation.
[Time split calculation]
GlobalTestSupply
www.
[Split time]
([Split
[Waiting
20
min,
30
min,
1
h,
2
h,
3
h,
[Waiting
reference].
area, select the auto save type.
setting in the numerical calculation.
from the start of measurement
time]) based on the
[Reference
[Split
time].)
reference].
4
h,
6
h,
8
h,
12
h,
1 d
.com
sales@GlobalTestSupply.com

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MEMORY HiLOGGER LR8450 and is the answer not in the manual?

This manual is also suitable for:

Memory hilogger lr8450-01Lr8450Lr8450-01

Table of Contents