*3: Slope example
With a level of 5°C and a time of 5 s
1. With a recording interval of 5 s
2. With a recording interval of 1 s
Alarm type
Pattern
Find Quality Products Online at:
An alarm will be output if the current measured value differs from the previous measured value by more
than 5°C.
Example data: 20°C, 25.1°C
An alarm will be output if the current measured value differs from the previous measured value by more
than 1°C for five data points in a row.
Example data: 20°C, 21.1°C, 22.2°C, 23.3°C, 24.4°C, 25.5°C
Setting description
1, 0,
X
Level
GlobalTestSupply
www.
Operation
[1]
Alarm
High
Low
[0]
High
Low
[X]
High
Low
Configuring Alarms
Description
Outputs an alarm
when the logic
signal is 1 (high).
Outputs an alarm
when the logic
signal is 0 (low).
Alarm
Not used in alarm
judgments.
Ignores the signal.