U2: Fault Trace - YASKAWA iQpump1000 Quick Start Manual

Ac drive
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

B.15 U: Monitors
No.
(Addr.
Name
Hex)
U1-83
Flow Rate
(0B9E)
U1-84
Accumulation Level -
(0B9F)
Millions
U1-85
Accumulation Level -
(0BA0)
Thousands
U1-86
Accumulation Level -
(0BA1)
Ones
U1-87
Accumulation Level -
(0BA2)
Decimal
U1-90
Pump Setpoint
(0BA5)
U1-91
Pump Feedback
(0BA6)
U1-92
Pump Status
(0BA7)
U1-93
Total Setpoint
(0BA8)
Compensation
U1-94
Motor Speed
(0BA9)
U1-97
Water Level
(0BAC)
U1-98
Suction Pressure
(0BAD)
U1-99
Anti-No-Flow Timer
(0BAE)
<1> The number of decimal places in the parameter value depends on the drive model and the ND selection. This value has two decimal places (0.01
A) if the drive is set for a maximum applicable motor capacity up to and including 11 kW, and one decimal place (0.1 A) if the maximum applicable
motor capacity is higher than 11 kW.
<2> When reading the value of this monitor via MEMOBUS/Modbus, a value of 8192 is equal to 100% of the drive rated output current.
<3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives.
<4> The display resolution depends on the ND selection. This value has two decimal places (0.01 kW) if the drive is set for a maximum applicable
motor capacity up to and including 11 kW, and one decimal place (0.1 kW) if the maximum applicable motor capacity is higher than 11 kW.
u

U2: Fault Trace

No.
(Addr.
Name
Hex)
U2-01
Current Fault
(0080)
U2-02
Previous Fault
(0081)
U2-03
Frequency Reference at
(0082)
Previous Fault
328
LCD Display
Displays the flow rate based on the pulse input frequency or the
analog voltage (flow rate input) and parameters P6-01 and
Flow Rate
P6-04.
A 2-second first order filter will be applied to this monitor.
Displays the recorded volume from the flow meter (pulse input
Volume * 1000000
or analog voltage).
Total volume is calculated as follows:
Volume * 1000
Total Volume = (U1-84 * 1000000) + (U1-85 * 1000) + U1-86
+ U1-87
Volume * 1
Volume * 0.0001
Displays the PID Setpoint.
Pump Setpoint
Displays the PID Feedback.
Pump Feedback
Displays Pump Running Status.
Pump Status
Displays the total absolute Setpoint Compensation.
Total SP Comp.
Displays the absolute value of the output frequency (U1-02)
Motor Speed
converted to RPM.
Displays the amount of water above the water level sensor.
Water Level
Displays the amount of suction pressure.
Suction Pressure
The Anti-No-Flow reduces the output frequency when this
ANF Timer
value reaches the P2-24 setting.
LCD Display
Displays the current fault.
Current Fault
Displays the previous fault.
Last Fault
Displays the frequency reference at the previous fault.
Frequency Ref
Description
U1 - 92= 00000000
Description
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
Analog
Output Level
Full scale: P6-01
setting
No signal output
available
No signal output
available
No signal output
available
1
Drive
1
Pump 2
1
Pump 3
No signal output
1
Pump 4
available
1
Pump 5
1
Pump 6
0
Not used
0
Not used
No signal output
available
No signal output
available
Full scale:
10 V = Q4-02
Full scale:
10 V = Q5-02
No signal output
available
Analog
Output Level
No signal output
available
No signal output
available
No signal output
available
Unit
dep. on
P6-04
dep. on
P6-16
dep. on
P1-02
dep. on
P1-02
dep. on
P1-02
1 RPM
0.1 ft.
0.1 PSI
or "Hg
0.1 s
Unit
0.01 Hz