U1-19
MEMOBUS/Modbus Error
Code
(0066)
U1-24
Input Pulse Monitor
(007D)
U1-25
Software number
(004D)
U1-26
SoftwareNumber ROM
(005B)
U1-50
Virtual Analog Input
(1199)
Expert

U2: Fault Trace

No.
Name
(Hex.)
U2-01
Current Fault
(0080)
U2-02
Previous Fault
(0081)
U2-03
Freq Reference@Fault
(0082)
U2-04
Output Freq @ Fault
(0083)
U2-05
Output Current@Fault
(0084)
U2-06
Motor Speed @ Fault
(0085)
U2-07
Output Voltage@Fault
(0086)
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the contents of the MEMOBUS/Modbus communication error where
error".
For example, U1-19 shows
bit0 : CRC Error
bit1 : Data Length Error
bit2 : Not used (normal value of [ ]).
bit3 : Parity Error
bit4 : Overrun Error
bit5 : Framing Error
bit6 : Timed Out
bit7 : Not used (normal value of [ ]).
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows the frequency to pulse train input terminal RP.
Unit: 1 Hz
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows the ID.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the ROM ID.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the virtual analog input value.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the fault that the drive has when viewing the monitor.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows the fault that occurred most recently.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows the frequency reference at the fault that occurred most recently.
Use U1-01 [Frequency Reference] to monitor the frequency reference value.
Unit: 0.01 Hz
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows the output frequency at the fault that occurred most recently.
Use U1-02 [Output Frequency] to monitor the actual output frequency.
Unit: 0.01 Hz
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the output current at the fault that occurred most recently.
Use U1-03 [Output Current] to monitor the actual output current. The keypad shows the value of U1-
03 in amperes (A).
When looking at the monitor through MEMOBUS/Modbus communications, the current is "8192 =
drive rated current (A)". Calculate the current from the monitor value that is in at MEMOBUS/
Modbus communications using "Numerals being displayed / 8192 × drive rated current (A).
Unit: When the drive model changes, the display units for this parameter also change.
• 0.01 A units: B001 - B018, 2001 - 2042, 4001 - 4023
• 0.1A units: 2056 - 2082, 4031 - 4060
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the motor speed at the fault that occurred most recently.
Use U1-05 [Motor Speed] to monitor the motor speed.
Unit: 0.01 Hz
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the output voltage reference at the fault that occurred most recently.
Use U1-06 [Output Voltage Ref] to monitor the output voltage reference.
Unit: 0.1 V
Description
= "error" and
when the drive detects a CRC error.
Description
1.17 U: Monitors
MFAO Signal Level
No signal output available
= "no
Determined by H6-02
No signal output available
No signal output available
Determined by H7-40
MFAO Signal Level
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available