INSPECTION
PLUNGER
Inspect plunger for wear. Replace if necessary.
MAGNETIC SWITCH
Push in plunger and release it. The plunger should return quickly
to its original position. Replace if necessary.
D Pull-In Coil Open Circuit Test
Check for continuity across magnetic switch 'S' terminal (1) and
'M' terminal (2). If no continuity exists, coil is open and should be
replaced.
D Hold-In Coil Open Circuit Test
Check for continuity across magnetic switch 'S' terminal (1) and
coil case. If no continuity exists, coil is open and should be re-
placed.
ARMATURE SHAFT BUSH
Inspect bushes for wear or damage. Replace if necessary.
CRANKING SYSTEM 6G-9