Avaya Definity SI Maintenance Manual page 306

Table of Contents

Advertisement

Maintenance Commands and Trouble-Clearing Aids
Output
After you complete the options screen, the system displays a 1- or 2-page Alarm
Report. To toggle between the pages and to exit the report, use the keys
described below:
For 513 and 715 terminals, use F8 for
commands
For all other terminals, use F7 for
Use Esc for the CANCEL command
The figure below is an example of an Alarm Report.
display alarms
Port
Maintenance
Name
02A
TONE-BD
01C07
ANL-BD
01C0702 ANL-LINE
01C0701 ANL-LINE
01C0703 ANL-LINE
01C1505 CO-TRK
01C1505 CO-TRK
02A0201 TONE-PT
02A
TDM-CLK
PN 02B
TDM-BUS
Command successfully completed
Field descriptions
Port
Maintenance
Name
On Brd
8-56
Issue 4 May 2002
ALARM REPORT
On
Alt
Alarm
Brd?
Name
Type
y
MAJOR
y
MINOR
n
311
WARNING
n
1051
WARNING
n
1053
WARNING
n
78/01
WARNING
n
78/01
WARNING
n
WARNING
n
WARNING
n
WARNING
Lists the location codes for the alarmed object, as follows:
Circuit packs locations display as:
cabinet-carrier-[slot]-[circuit]. Example: 01C0702.
Port network locations display as: port network number-bus.
Example: PN 02B. PN 02 = Port Network (PN) number and
A or B = bus.
Fiber link locations display as: fiber link number-PNC side.
Example: x A-PNC. "X" = fiber link number and "A" = PNC
side [A or B].
Lists the logical name of the maintenance object with the alarm.
A y (yes) indicates the fault was found on the associated circuit
pack. An n (no) indicates the fault is not connected to the circuit
pack.
and
NEXT PAGE
PREV PAGE
and
NEXT PAGE
PREV PAGE
Svc
Ack?
Date
State 1 2
Alarmed
y n
05/22/20:34 00/00/00:00
n n
05/22/20:26 00/00/00:00
IN
05/22/20:26 00/00/00:00
IN
05/22/20:26 00/00/00:00
IN
05/22/20:26 00/00/00:00
OUT
05/22/20:26 00/00/00:00
OUT
05/22/20:26 00/00/00:00
05/22/20:34 00/00/00:00
05/23/13:43 00/00/00:00
05/23/14:53 00/00/00:00
commands
Date
Resolved
555-233-123