Busyout Trunk - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

busyout trunk

Field descriptions
Port
Maintenance Name
Alt. name
Result
Error Code
busyout trunk
This command places the specified installed or uninstalled trunk group or trunk
group member in a maintenance busy state. No periodic or scheduled tests are
performed on the busied out trunk groups or trunk group members until they are
released. When the object is maintenance busy it is deactivated (no call
processing activity may include the busied object). A single group member can be
busied out by specifying the group and member number. All members in a trunk
group can be busied out by specifying the trunk group number. Warning alarms
(error type 18) are generated on each busied out maintenance object, so that
INADS can access the state of the objects. The release trunk command
reactivates the specified trunk group or group member.
NOTE:
If the user enters busyout trunk <group number>/, the lowest port-location
in the group is busied out. This is NOT recommended.
Action/
Object
Qualifier
busyout
group
trunk
member
555-233-123
Tone/clock board address (cabinet-carrier)
Circuit pack name:
TONE-PT
Not applicable
Test result: Pass, Abort, Fail
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of codes by test number for each MO.
Qualifier Description
Trunk group number (1–99)
Number of a trunk within a
trunk group (1 – 99)
Examples:
busyout trunk 78
busyout trunk 78/1
,
TDM-CLK
,
TONE-BD
Feature
Logins
Defaults
Interactions
init
none
none
inads
craft
Issue 4 May 2002
8-23