Avaya Definity SI Maintenance Manual page 254

Table of Contents

Advertisement

Maintenance Commands and Trouble-Clearing Aids
Output
The following example shows the output from the busyout board 1c07
command, and assumes that board in cabinet 1, carrier c, slot 7 is an analog
board with three administered ports. The responses display on a test-by-test basis
with one line of data for each test result.
busyout board 01C07
Port
Maintenance Name
01C07
ANL-BD
01C0702
ANL-LINE
01C0701
ANL-LINE
01C0703
ANL-LINE
Command successfully completed
Field descriptions
Port
Maintenance
Name
Alt. Name
Result
Error Code
8-4
Issue 4 May 2002
COMMAND RESULTS
Alt. Name
Result
PASS
PASS
51001
PASS
PASS
Port address (cabinet-carrier-slot-circuit)
The name of maintenance object
Alternate way to identify maintenance objects.
If the Object is The field contains
station
extension
trunk
xxx/yyy (xxx = trunk group, yyy = member)
private CO line P/xxx (xxx = private CO line group number)
Test result: Pass, Abort, or Fail
Numeric code explaining why the release failed or aborted. Refer to
the detailed list of the codes by test number for each MO.
SPE A
Error Code
555-233-123