Busyout Station - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

busyout station

Output
The following example is a display of the busyout spe-standby command.
busyout spe-standby
Port
Maintenance Name
01B
STBY-SPE
Command successfully completed
Field descriptions
Port
Maintenance
Name
Alt. Name
Result
Error Code
busyout station
This command places the installed and uninstalled administered voice terminal
extension (station) in a maintenance busy state. No periodic or scheduled tests
are performed on the busied out station until it is released. When the object is
maintenance busy it is deactivated (no call processing activity can include the
busied object). Warning alarms (error type 18) are generated on each busied out
maintenance object, so that INADS can determine the state of the objects. The
command, release station, reactivates the specified voice terminal extension.
Action/
Object
Qualifier
busyout
extension
station
555-233-123
COMMAND RESULTS
Alt. Name
Result
PASS
Standby SPE cabinet and carrier location (01A or 01B)
Always STBY-SPE
Blank
Test result: Pass, Abort, Fail
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of codes by test number for each MO.
Qualifier Description
Extension number (per
dial-plan)
Examples:
busyout station 10020
busyout station 32770
SPE A
Error Code
Logins
Defaults
init
none
inads
craft
Issue 4 May 2002
Feature
Interactions
none
8-19