Change System-Parameters Maintenance - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

Maintenance Commands and Trouble-Clearing Aids
change system-parameters
maintenance
This command specifies and displays scheduled maintenance operations and
maintenance support functions. It also activates and deactivates INADS alarm
origination during repairs. To deactivate alarm origination:
1. Make a note of the current entries in the Alarm Origination and CPE Alarm
fields so you can restore them later.
2. Change the Alarm Origination to OSS Numbers field to "neither."
3. Change the CPE Alarm Activation Level field to none.
4. If daily scheduled maintenance must remain idle during a maintenance
procedure, set the Start Time field to a time after the session ends. If
daily Scheduled Maintenance is running and needs to be deactivated, set
the Stop Time field to one minute after the current time.
5. Press
Command successfully completed
Action/Object
Qualifier
change
system-
parameters
maintenance
8-34
Issue 4 May 2002
and verify that the screen displays the message:
Enter
NOTE:
For earlier releases of system software, disable Cleared Alarm
Notification and Restart Notification before submitting the form.
NOTE:
When finished working on the switch be sure to return all fields to
their original settings.
Qualifier
Description
Examples:
change
system-parameters
maintenance
Feature
Logins
Defaults
Interactions
init
none
none
inads
craft
cust
rcust
555-233-123