Maintenance Commands and Trouble-Clearing Aids
Action/
Object
Qualifier
busyout
pms-log
journal-
printer
wakeup-log
Feature Interactions
Maintenance of a component on a link sometimes interferes with the maintenance
of the link itself. For example, maintenance can put a link component in a busy
state causing link set-up to fail. Frequent attempts at re-setup of a link may delay
the recovery of a faulty component, due to the maintenance test only taking place
when the component is idle. Disable the attempted re-setup of a link with busyout
and the link remains intact. If the link is already down, busyout stops periodic
re-setup attempts on the link.
Output
The following shows the output for busyout journal-printer wakeup-log.
busyout journal-printer wakeup-log
Port
Maintenance Name
0
JRNL-LINK
Field descriptions
Port
Maintenance Name
Alt. Name
Result
Error Code
8-8
Issue 4 May 2002
Qualifier Description
Link to pms (in output, port
name for pms link =1)
Link to the wakeup logging
facility (in output, port name =
0)
Examples:
busyout journal-printer
pms-log
busyout journal-printer
wakeup-log
COMMAND RESULTS
Alt. Name
Result
PASS
Physical object port address:
The name of the maintenance object
Not applicable
Test result: Pass, Abort, Fail
Numeric code explaining why the release failed or aborted.
Refer to the list of the codes by test number for each MO.
Feature
Logins
Default
Interactions
init
None
See below
inads
craft
nms
SPE A
Error Code
0
= wakeup log,
1
= pms log