display alarms
Alt Name
Alarm Type
Service
State
Ack?
Date Alarmed
Date
Resolved
555-233-123
Identifies the location of maintenance object, as follows:
Station = extension number
Trunk = Group number (78/__) or group and member
numbers (78/01)
Private CO Line = private CO line (P) and group number.
(P/xxx)
Alarm level: MAJOR, MINOR, or WARNING
Identifies the service state of the station and trunk ports, as
follows:
RDY = ready for service
OUT = out of service
IN = in service
[Blank] = No associated service state
Headings 1 and 2 identify the first and second OSS telephone
numbers, respectively. The entries below indicate the
acknowledged alarm state:
Y (yes) = alarm has been acknowledged
N (no) = alarm has not been acknowledged
C (cleared) = alarm was first acknowledged, then resolved
and cleared
[Blank] = no attempt was made to report the alarm
NOTE:
If the user disables the alarm origination with the
change system-parameters maintenance
command, then the Ack? field is blank regardless of
the true acknowledged state of the alarm.
Indicates the month, day, hour, and minute of the alarm.
Indicates the month, day, hour, and minute of the resolution. For
active alarms, this field contains zeros (0).
Issue 4 May 2002
8-57