Maintenance Commands and Trouble-Clearing Aids

monitor health

Use monitor health to see the current system alarm summary, maintenance busy
summary, user summary, critical system status, and cabinet status that are
updated each minute.
Action/
Object
Qualifier
monitor
health
Output
The following example is a display of monitor system health.
status health
ALARM SUMMARY
Major:
0
Minor:
9
Warning:
4
BUSY-OUT SUMMARY
Trunks:
0
Stations:
0
Others:
0
PROCESSOR OCCUPANCY STATUS
Static:
3%
SM:
CP:
10%
Idle:
CRITICAL SYSTEM STATUS
Active SPE: A/auto
Duplicated? SPE:n
SPE Power: commercial
Time Source: external
# Logins: 2
8-226
Issue 4 May 2002
Qualifier
Description
Logins
init
inads
craft
cust
nms
browse
CABINET STATUS
Emerg
Alarms
Cab Trans Mj Mn Wn PNC
1
off
0| 7| 0 up
2
off
0| 0| 4 up
3
n.a.
0| 2| 0 up
4
off
0| 0| 0 up/up
6%
81%
- Press CANCEL to quit -
Feature
Default
Interactions
none
If standby SPE Emergency
Transfer Select Switches change
and handshakes are down, the
displayed Emerg Trans field is
incorrect until handshake
reintializes.
When the monitor health
command terminates, users are
logged off of the system.
9:33 TUE JAN 29 1991