display communication-interface processor-channel
Field descriptions
Proc Chan
Enable
Appl.
Gtwy To
Mode
Interface Link
Interface Chan
Destination Node
Destination Port
Session Local
Session Remote
Mach ID
555-233-123
Displays the BX.25 virtual channel number or the TCP/IP
listen port channel to carry this processor (virtual) channel.
Type y to enable a processor channel. Type n to disable a
processor channel.
Identifies the switch application used over this link. The
application gateway is used for conversion between ISDN
and either TCP/IP or BX.25. Use the gtwy-tcp entry for
conversion between BX.25 and TCP/IP. Valid entries are:
audix, dcs, fp-mwi, gateway, gtwy-tcp, mis, msaamwl,
msaclk, msahlwc, msallwc, msamcs, qs-mwi, blank
Identifies which processor channel the given processor
channel is serving as a gateway to. Valid entries are a
number between 1-(maximum number of processor
channels), or blank.
Identifies whether the IP session is passive (client) or active
(server). This field must be blank if the type of interface link
is x.25 (r model) or procr-intf (si model). This field cannot be
blank if the type of interface link is ethernet or ppp. Valid
entries are client, server, or blank.
Identifies the physical link carrying this processor (virtual)
channel. Links numbered 1 through (4 times the number of
PI circuit packs) for the si model can be either x.25 or tcp/ip.
The rest of the links (up to 25) must be tcp/ip.
Identifies the BX.25 virtual channel number or the TCP/IP
listen port channel to carry this processor (virtual) channel.
The channel number 0 means any port can be used. Valid
entries for link type x.25 are 1-64; for Ethernet or ppp, 0,
5000-64500.
Identifies the switch or adjunct at the far end of this link.
Enter an adjunct name, switch name, far end IP address,
node ID, or leave blank for services local to this switch.
Identifies the port number of the destination. The number 0
means any port can be used. Valid entries are 0,
5000-64500.
Field ported forward from R6.
Field ported forward from R6.
Field ported forward from R6.
Issue 4 May 2002