Maintenance Commands and Trouble-Clearing Aids
Field descriptions
Port
Alt. Name
Maintenance Name
Result
Error Code

busyout tone-clock

This command places the specified tone/clock in a maintenance busy state. No
periodic or scheduled tests are performed on the busied out object until it is
released. When the object is maintenance busy it is deactivated (no call
processing activity may include the busied object). Warning alarms (error type 18)
are generated on each tone clock circuit pack busied out, so that INADS can
determine the state of the objects. The command, release tone-clock,
reactivates the specified tone/clock.
Action/
Object
Qualifier
busyout
location
tone-clock
Output
The following example is a display of the busyout tone-clock command.
busyout tone-clock 1a
Port
Maintenance Name
01A
TONE-PT
01A
TDM-CLK
01A
TONE-BD
Command successfully completed
8-22
Issue 4 May 2002
Port address and associated TDM number and bus (PNA or
PNB)
Not applicable
Type of busied out maintenance object:
Test result: Pass, Abort, Fail
Numeric code explaining why the release failed or aborted.
Refer to the list of codes by test number for each MO.
Qualifier Description
Physical location (PC)
Examples:
busyout tone-clock 01c
busyout tone-clock 03d
COMMAND RESULTS
Alt. Name
Result
PASS
PASS
PASS
TDM-BUS
Feature
Logins
Defaults
Interactions
init
1 (one)
none
inads
craft
SPE A
Error Code
555-233-123