Avaya Definity SI Maintenance Manual page 337

Table of Contents

Advertisement

display events
Table 8-2. Denied IP events — Continued
Event
Event
Type
Description
1923
IP RRJ-No E164
number
1924
IP RRJ-No GRQ
msg rcvd
1925
IP RRJ-RQ: new
LM fail
1926
IP
RRJ-Authenticatio
n fail
1927
IP RRJ-Invld
station type
1928
IP
RRJ-StnTyp/Proto
cl err
1929
IP RRJ-No idx for
MMCmplx
555-233-123
Explanation
Registration rejected; no valid E.164
phone number available. The
extension is not administered.
Registration rejected; did not receive
a Gatekeeper Request message
Registration rejected; failure creating
a new Login Manager. Possible
cause:
No available heap memory to
create LoginMgr
Cannot start LoginMgr timer
Clock not set
Registration rejected: authentication
failure. The password that the user
entered and the administered
password on the station screen do
not match.
Registration rejected:
invalid set type
no Remote Office or IP
Softphone administration on the
station screen
Registration rejected: station type and
call signalling protocol are
inconsistent. The IP Softphone
should be defined as either of the
following:
DCP ext with call control equal to
IP Softphone
H.323 ext with call control equal
to none
Registration rejected: dual-connected
DCP set user record is missing the
index for the multimedia complex.
Event
Event
Data 1
Data 2
UID
IP address
UID
IP address
UID
IP address
UID
IP address
UID
Type
UID
Endpoint type
(3rd and 2nd
nyble); call
signalling
protocol (low
nyble)
UID
IP address
Continued on next page
Issue 4 May 2002
8-87

Advertisement