Chapter 8: Clock controller maintenance
Contents
This section contains information on the following topics:
Clock operation
Tracking mode
Free run (non-tracking) mode
Reference clock errors
Automatic clock recovery
Automatic clock switching
Clock controller commands (LD 60)
Replace the clock controller
Task summary list
Set switches
Clock controller cabling
Clock operation
Tracking mode
In tracking mode, the PRI loop supplies an external clock reference to a clock controller (CC).
See
Figure 14: Clock controller primary and secondary tracking
can operate in tracking mode, with one defined as the primary reference source for clock
synchronization, the other defined as the secondary reference source. The secondary
reference acts as a backup to the primary reference.
ISDN Primary Rate Interface Maintenance
on page 77
on page 77
on page 78
on page 78
on page 79
on page 79
on page 80
on page 81
on page 81
on page 82
on page 83
on page 78. Two PRI loops