2 In the Agent dialog, select SNMP Enabled.
3 Click Retrieve MIB Files to obtain a file listing the MIBs defining the managed object properties.
The Retrieve MIB Files dialog is displayed.
4 Click Browse and navigate to the desired directory to save the MIB files.
5 Click OK.
The path of the selected directory is displayed in the Retrieve MIB Files dialog.
6 Click Save.
The MIB files are saved to the selected directory.
7 Click Close to exit the Retrieve MIB Files dialog.
8 In the Agent dialog, define the parameters allowing the SNMP Management System and its user to
easily identify the MCU.
Collaboration Server-SNMP Properties - Agent Options
Field
Contact person for
this MCU
MCU Location
MCU System Name
9 Open the Traps tab.
Traps are messages sent by the MCU to the SNMP Managers when events such as MCU Startup or
Shutdown occur. Traps may be sent to several SNMP Managers whose IP addresses are specified
in the Trap Destinations field.
10 Define the following parameters:
SNMPv3 - Traps
Field
SNMP Trap Version
Polycom, Inc.
Description
Type the name of the person to be contacted in the event of problems with the
MCU.
Type the location of the MCU (address or any description).
Type the MCU's system name.
Description
Specifies the version, either Version 1 2 or 3 of the traps being sent to the IP
Host. Polycom software supports the standard SNMP version 1 and 2 traps,
which are taken from RFC 1215, convention for defining traps for use with
SNMP.
Note: The SNMP Trap Version parameters must be defined identically in the
external SNMP application.