Omron R88M-K User Manual page 672

Ac servomotors/servo drives g5-series with built-in ethercat communications
Hide thumbs Also See for R88M-K:
Table of Contents

Advertisement

Appendices
Event name
External Encoder Status Error 4
Meaning
Bit 04 of the external encoder error code (ALMC) was set to 1.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
Bit 04 of the external encoder error
code (ALMC) was set to 1.
Attached
None
information
Precautions/
"51" is displayed on the Servo Drive front panel and F451 is given as the AlarmCode (4001 hex).
Remarks
Event name
External Encoder Status Error 5
Meaning
Bit 05 of the external encoder error code (ALMC) was set to 1.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
Bit 05 of the external encoder error
code (ALMC) was set to 1.
Attached
None
information
Precautions/
"51" is displayed on the Servo Drive front panel and F551 is given as the AlarmCode (4001 hex).
Remarks
A-122
Source details
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
---
Remedy
Check the external encoder
specifications and take suitable
corrective actions.
Source details
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
---
Remedy
Check the external encoder
specifications and take suitable
corrective actions.
G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
Event code
08120000 hex
Slave
Detection
timing
Error reset (after
Log category
cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherCAT LINK/ACT
---
Name
---
Prevention
Take preventative actions according
to the external encoder specifications.
Event code
08130000 hex
Slave
Detection
timing
Error reset (after
Log category
cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherCAT LINK/ACT
---
Name
---
Prevention
Take preventative actions according
to the external encoder specifications.
Continuously
System
Continuously
System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kn-ect

Table of Contents