Omron R88M-K User Manual page 660

Ac servomotors/servo drives g5-series with built-in ethercat communications
Hide thumbs Also See for R88M-K:
Table of Contents

Advertisement

Appendices
Event name
Overvoltage
Meaning
The power supply voltage exceeded the allowable input voltage range.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
The voltage between the positive and
negative terminals in the control
power supply converter exceeded the
specified value.
The voltage was suddenly increased
by the phase advance capacitor or
the uninterruptible power supply
(UPS).
The Regeneration Resistor wiring is
broken.
The External Regeneration Resistor
is not suitable.
The Servo Drive failed.
Attached
None
information
Precautions/
"12" is displayed on the Servo Drive front panel and F012 is given as the AlarmCode (4001 hex)
Remarks
A-110
Source details
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
---
Remedy
Input the correct voltage.
Remove the phase-advancing
capacitor or UPS.
Measure the resistance of the
external resistor between the B1 and
B2 terminals on the Servo Drive. If the
resistance is infinite, the wiring is
broken. Replace the external resistor.
Change the Regeneration Resistor
based on the specified regeneration
resistance and the calculated power
(W).
Replace the Servo Drive.
G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
Event code
04A90000 hex
Slave
Detection
timing
Error reset (after
Log category
resetting slave
errors)
Power drive circuit is OFF for relevant slave.
EtherCAT LINK/ACT
---
Name
---
Prevention
Input the correct voltage.
Do not use a phase-advancing
capacitor or UPS.
None
Determine the Regeneration Resistor
based on the specified regeneration
resistance and the calculated power
(W).
None
Continuously
System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kn-ect

Table of Contents