Omron R88M-K User Manual page 560

Ac servomotors/servo drives g5-series with built-in ethercat communications
Hide thumbs Also See for R88M-K:
Table of Contents

Advertisement

Appendices
1) Example of Servo OFF during Operation in csp
Actual speed
6041 hex: Bit 9
6041 hex: Bit 10
(Target reached)
6041 hex: Bit 12
(Target position ignored)
6041 hex: Bit 13
(Following error)
4000 hex: Bit 1
4000 hex: Bit 4
4000 hex: Bit 7
4000 hex: Bit 8
*1 When the servo is turned OFF, a deceleration stop starts and 6061 hex continues to show the same mode as
the mode of operation (csp) specified in 6060 hex.
*2 After the motor stops, No mode assigned is shown by 6061 hex.
*3 Bit 12 will be 0 during a deceleration due to servo OFF.
Note The operation during the interval from A to B for drive prohibition and main circuit power OFF is the same as
when the servo is turned OFF.
A-10
*1
A
Servo ON
30 r/min
PDS state
Operation enabled
6060 hex
6061 hex
csp
(Remote)
*3
1
0
0/1
0
(DEN)
(VLIM)
(VCMP)
0/1
(NEAR)
G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
Servo OFF
*2
B
Switched on
csp
No mode assigned
1
0
0
0
1
0
0
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kn-ect

Table of Contents