4 System Design
Regeneration
absorption
*1
capacity
Model
Resistance
*2
value
Connection
method
*1 Select a combination that has an absorption capacity greater than the average regeneration power (Pr).
*2 Do not use a combination with resistance values lower than the allowable minimum regeneration resistance of
each drive. For information on the allowable minimum regeneration resistance, refer to 4-4-2 Servo Drive Regenera-
tion Absorption Capacity on page 4-58.
Precautions for Safe Use
• Surface temperatures on regeneration resistance can reach 200°C.
Do not place objects that tend to catch fire nearby. To prevent people from touching them,
install a cover that enables heat dissipation.
4-62
180 W
R88A-RR50020S
20 Ω
R
G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
360 W
R88A-RR50020S
10 Ω
R
R
R
R
1440 W
R88A-RR50020S
10 Ω
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kn-ect

Table of Contents