10 Operation
Normal Display (LED Display Selection (3700 hex) set to 0)
Main power supply
turned ON and EtherCAT
communications
established.
Servo ON
Error occurs
Error Display
*1
The main error code flashes
as a decimal (example for an overload).
*1 : "
" will flash when a Safety Input Error (Error No. 30.0) occurs.
"
" does not flash on the display.
EtherCAT Status Indicators
Check the status of the status indicators.
If the RUN indicator will not turn ON or the ERR indicator will not turn OFF, refer to Status Indicators on
page 5-3 and check the status.
10-6
A
Main power supply
interrupted and EtherCAT
communications not
established.
Servo OFF
Error cleared
G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
+ Dot on right lights.
+ Dot on right lights.
Warning occurs
Warning Display
The hexadecimal warning code and the
normal display are displayed alternately
(example for an overload).
Warning code
Normal code
(for 2 s)
(for approx. 4 s)
Warning cleared

Hide quick links: