Depth Setting
This is the I/O ratio at which the center frequency input is completely cut off at a set value of 0 and
completely passed at a set value of 100. If the indication unit is [dB], this value should conform to the
right column in the table below.
Set value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
10
5
0
-3[dB]
-5
-10
-15
-20
-25
-30
1
0
G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
Width
Bandwidth/center
frequency
0.50
0.59
0.71
0.84
1.00
1.19
1.41
1.68
2.00
2.38
2.83
3.36
4.00
4.76
5.66
6.73
8.00
9.51
11.31
13.45
16.00
Notch filter frequency characteristics
1
0
0
Frequency [Hz]
11 Adjustment Functions
Depth
Set value
I/O ratio (%)
0
0 (Cut off)
1
1
2
2
3
3
4
4
5
5
10
10
15
15
20
20
25
25
30
30
35
35
40
40
45
45
50
50
60
60
70
70
80
80
90
90
100
100 (Passed)
Depth 0, width 4
Depth 50, width 4
Depth 0, width 8
1
0
0
0
Damping factor (dB)
11
−∞
−40.0
−34.0
−30.5
−28.0
−26.0
−20.0
−16.5
−14.0
−12.0
−10.5
−9.1
−8.0
−6.9
−6.0
−4.4
−3.1
−1.9
−0.9
0.0
11-25