Mounting The Scanner Motor; Adf Open/Close Sensor; Removing The Reader Unit Rear Cover - Canon iR6570 series Service Manual

Hide thumbs Also See for iR6570 series:
Table of Contents

Advertisement

Chapter 5
[2]

5.4.7.3 Mounting the Scanner Motor

When mounting the scanner motor, check to make sure that the timing
belt [3] is properly fitted to the scanner pulley [1] and the motor shaft
[2].
[3]
[2]

5.4.8 ADF Open/Close Sensor

5.4.8.1 Removing the Reader Unit Rear Cover

1) Open the cable clamp [1].
2) Disconnect the 2 connectors [2].
3) Remove the 2 screws [3].
5-30
[1]
F-5-90
0008-7860
[1]
F-5-91
[3]
F-5-92
0009-2996
[2]
[3]
4) Bend up the rubber cover [1], and remove the 2 screws [2] each; then,
detach the 2 angle guide plates [3].
1]
2]
5) Fully open the ADF.
6) Remove the 3 screws [1], and slide the reader unit rear cover [2] to
the rear to detach.
Take care not to damage the ADF open/closed sensor arm [3].
[1]
F-5-93
2]
3]
F-5-94
1]
3]
F-5-95