4.2.10 The message "PLATEN IS OPEN CLOSE THE PLATEN Unit" fails
to go OFF.
Sensor flag
1) Is the reader unit slide detecting switch (SW1) damaged or dis-
YES: Correct it. If damaged, replace it.
Connector
2) Is the connection between the connector of the reader unit slide de-
NO:
Reader unit slide detecting switch (SW1), Image processor PCB
3) Try replacing the reader unit slide detecting switch (SW1). Is the
YES: End.
NO:
7-46
COPYRIGHT © 2001 CANON INC.
placed?
tecting switch (SW1) and the connector J314 on the image proces-
sor PCB normal?
Correct the connection.
problem corrected?
Replace the image processor PCB.