Ricoh MP C6502SP Field Service Manual page 1070

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

5. Troubleshooting
SC No.
SC No.
SC395-01
SC395-02
SC395-03
SC395-04
SC395-05
SC396-01
SC396-02
SC396-03
SC396-04
SC396-05
SC397-01
SC397-02
SC397-03
SC397-04
SC397-05
1068
Level
Error Name/Error Condition/Major Cause/Solution
Vd(700) lesser than 500[-V]
Details:
In Vd detection, which is done at the beginning of process control, the
measured potential (Vd) is converted to the potential when -700 V is
applied to the drum (Vd700) and used to check the potential sensor.
• Potential sensor probe connector disconnected
• Potential sensor probe defective
• Disconnect and reconnect the harness connecting the IOB and
potential sensor board, then check the sensor again.
• If this does not solve the problem, replace the potential sensor
probe.
Level
Error Name/Error Condition/Major Cause/Solution
D
Drum motor (K) Lock: Encoder 1 error
D
Drum motor (K) Lock: Encoder 2 error
D
Drum motor (K) Lock: Encoder 1/2 error
D
Drum motor (K) Lock: Hole error
D
Drum motor (K) Lock: Overload error
D
Drum motor (C) Lock: Encoder 1 error
D
Drum motor (C) Lock: Encoder 2 error
D
Drum motor (C) Lock: Encoder 1/2 error
D
Drum motor (C) Lock: Hole error
D
Drum motor (C) Lock: Overload error
D
Drum motor (M) Lock: Encoder 1 error
D
Drum motor (M) Lock: Encoder 2 error
D
Drum motor (M) Lock: Encoder 1/2 error
D
Drum motor (M) Lock: Hole error
D
Drum motor (M) Lock: Overload error

Advertisement