Ricoh MP C6502SP Field Service Manual page 1160

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

5. Troubleshooting
SC No.
SC514-00
1158
Level
Error Name/Error Condition/Major Cause/Solution
Inverter Junction Gate Motor Error
Inverter junction gate home position sensor did not turn on or off within
150msec from the start of home position detection operation (motor drive
start).
Details:
If detected for the first or second time:
• During paper transport, this is not handled as a jam/SC; paper is
fed normally and the error counter increases.
• Otherwise (during initialization), a jam alert is displayed to instruct
the user to remove jammed paper, and the error counter increases.
If detected for the third time:
• Displays the SC No. on the operation panel.
D
• Inverter junction gate motor defective/connector disconnected/
harness broken
• Inverter junction gate home position sensor defective/connector
disconnected/harness broken
• Circuit board (PFB, DUB) defective
• Junction gate/junction gate drive unit does not move e.g. because
physical obstacle (piece of paper, etc.) is blocking operation.
• Inverter junction gate motor and inverter junction gate home position
sensor check/cleaning/replacement/harness reconnection/
harness replacement
• Check or replace the circuit board (PFB, DUB).
• Check and/or replace the inverter junction gate and inverter
junction gate drive unit.

Advertisement