Ricoh MP C6502SP Field Service Manual page 1168

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

5. Troubleshooting
SC No.
SC625-00
SC No.
SC626-01
D135 RTB 54
SC626-01
D137 RTB 77
SC626-02
SC626-03
1166
Level
Error Name/Error Condition/Major Cause/Solution
TDCU communication error.
ASAP communication protocol error
• A BREAK signal was detected at power-on.
• Non-response (100 ms) was detected 3 times consecutively during
normal operation.
D
• NAK was received 3 times before ACK was received during normal
operation.
• A BREAK signal was detected during normal operation.
• IOB defective
• Replace the IOB.
Level
Error Name/Error Condition/Major Cause/Solution
D
DUB communication error at power-on
D
DUB communication error during normal operation
D
DUB BREAK detection during normal operation