Ricoh MP C6502SP Field Service Manual page 1121

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

SC No.
Level
SC505-04
B
SC No.
Level
SC505-11
B
Error Name/Error Condition/Major Cause/Solution
LCT Tray Error (Paper Overload Error): D709
During tray initialization, the upper limit sensor and the lower limit sensor
were both on for 5 times consecutively.
• Paper overloaded.
• Upper limit sensor defective/connecter disconnected
• Lower limit sensor defective/connecter disconnected
• Related harness broken
• PCB defective
• Reduce loaded paper.
• Replace or reconnect the upper limit sensor.
• Replace or reconnect the lower limit sensor.
• Replace the corresponding harness.
• Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
LCT Tray Error (Upper Limit Detection Error): D710
At the start of tray initialization, the upper limit sensor was detected as
being off for 5 times before the pick-up solenoid was on.
• Pick-up solenoid defective/connecter disconnected
• Upper limit sensor defective/connecter disconnected
• Related harness broken
• PCB defective
• Replace or reconnect the pick-up solenoid.
• Replace or reconnect the upper limit sensor.
• Replace the corresponding harness.
• Replace the PCB.
Service Call 501-595
1119

Advertisement

Chapters

Table of Contents
loading

Table of Contents