5. Troubleshooting
* 1.90 is the default environment coefficient set for Environment Coefficient 9.
IMPORTANT
If you are not sure whether the uneven density problem you are trying to resolve is "Banding in
2-3mm pitch" or not, do the following procedure.
A) Set SP2-225-032 through 041 to "1.50", and print the job showing the problem.
B) Set SP2-225-032 through 041 to "1.63", and print the job showing the problem.
C) Set SP2-225-032 through 041 to "1.76", and print the job showing the problem.
If the problem does not occur in condition A, but occurs either in conditions B or C, the problem is
judged to be Banding in 2-3mm pitch.
• DO NOT print more than 10 pages with the above modified SP setting. Make sure to set each
SP back to default after the test.
Environment Coefficient
Side effect
Increased lubricant consumption
Troubleshooting for Banding Caused by the PCDU (Pro C5110S/Pro C5100S)
Symptom / Cause
Bands (uneven density) in a certain pitch appear across the entire page. The problem is caused by
the vibration of the components of the PCDU.
1418
1
2
3
4
5
6
7
8
9
10
SP number
SP2-225-032
SP2-225-033
SP2-225-034
SP2-225-035
SP2-225-036
SP2-225-037
SP2-225-038
SP2-225-039
SP2-225-040
SP2-225-041
Default
0.70
0.83
0.96
1.10
1.30
1.50
1.63
1.76
1.90
2.00

Advertisement