Ricoh MP C6502SP Field Service Manual page 1131

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

SC No.
Level
SC526-02
D
SC No.
Level
SC527-01
D
SC527-02
D
SC527-03
D
SC527-04
D
SC527-05
D
SC527-06
D
SC527-07
D
SC527-08
D
SC No.
Level
SC530-01
D
SC530-02
D
SC530-03
D
SC530-04
D
SC530-05
D
SC530-06
D
SC530-07
D
Error Name/Error Condition/Major Cause/Solution
Transport Motor 2 Rotation Error
2 seconds after motor startup, the motor lock error signal (LOCK signal)
was detected for 1200 msec or more.
• Motor defective
• Harness broken
• Circuit board defective
• Replace the motor.
• Reconnect the connector.
Error Name/Error Condition/Major Cause/Solution
Cooling Fan Alarm 1
Cooling Fan Alarm 2
Cooling Fan Alarm 3
Cooling Fan Alarm
Exhaust Fan Alarm 1
Exhaust Fan Alarm 2
Exhaust Fan Alarm 3
Exhaust Fan Alarm 4
Error Name/Error Condition/Major Cause/Solution
Fusing Pressure Roller Intake Fan Lock (D137/D138 only)
Fusing Pressure Roller Exhaust Fan Lock (D137/D138 only)
Heat Pipe Panel Intake Fan Lock
Heat Pipe Panel Exhaust Fan Lock
Fusing Exit Exhaust Fan Lock
ITB Cleaning Intake Fan Lock
IH Coil Cooling Fan Lock
Service Call 501-595