5. Troubleshooting
Solution
Clean the heat pipe unit.
See Procedure below.
Procedure
1. Remove the fusing unit.
2. Open the separation unit [A] and remove the heat pipe unit [B] (5 screws).
3. Remove the toner stuck to the heat pipe rollers using sandpaper (#1500).
• Move the sandpaper back and forth horizontally and rotate the heat pipe roller to clean
it full-circle.
4. Wipe the places that you sanded in Step 3 with a damp cloth.
1458