5. Troubleshooting
SC No.
SC551-00
1140
Level
Error Name/Error Condition/Major Cause/Solution
Sensor 4: Pressure Roller Center Disconnection
0 degrees or lower was detected for (t1) seconds consecutively.
Number of times: 10 or more
D135 (Japan): 75 (seconds)
D136 (Japan)/D135 (NA): 75 (seconds)
D136 (NA)/D135 (EU)/D136(EU): 75 (seconds)
D137 (Japan): 75 (seconds)
D138 (Japan)/D137 (NA)/D138 (NA)/D137 (EU)/D138 (EU): 75
(seconds)
A
Monitored at: All times, though SC is not issued when temperature is not
controlled (when in off mode/sleep mode, when a door, excluding the
toner supply door, is open, or when the heater relay is off).
• Thermopile disconnection
• Connecter contact failure
• Replace the thermopile.
• Reconnect the connector.
• Replace the connector.
• Replace the connector.