4. Replacement and Adjustment
• Execution time for filling developer is 60 seconds as the default. The time interval for execution
can be adjusted. If more time is needed to empty the developer pack, increase the time
interval with SP3-024-11 (Developer Fill: Exe Drive Time Upper Limit).
• If the filling is not completed in time, see the result code table below.
8. After the filling completion message is displayed on the touch panel display, enter SP3-025-001
(Dev Fill OK? From Left:YMCK) to confirm that developer installation succeeded.
You will see a 4-digit number: 1111. Reading from left-to-right each number is a result code for the
Y, M, C, K developer execution with SP3-024-00. Refer to the result code table below.
Result code table for filling developer
Code
Meaning
No
0
execution
714
Comment
Conditions
-
-
Recovery Procedure
-