Ricoh MP C6502SP Field Service Manual page 1042

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

5. Troubleshooting
SC No.
SC No.
SC204-01
SC204-03
1040
Level
Error Name/Error Condition/Major Cause/Solution
The XSCRDY signal (polygon ready) never becomes inactive (H) after the
polygon motor went OFF.
• The interface harness to the polygon motor driver damaged or not
connected correctly.
• Polygon motor or polygon motor driver defective
• Polygon motor drive pulse cannot be output correctly. (Polygon
controller)
• XSCRDY signal observation failing (Polygon controller)
• Cycle the machine off/on.
• Replace the laser unit.
• Replace the polygon harness.
• Replace the IPU board.
Level
Error Name/Error Condition/Major Cause/Solution
D
Polygon Motor: XSCRDY Signal Error: Bk
D
Polygon Motor: XSCRDY Signal Error: Ma
During polygon motor rotation, the XSCRDY signal was inactive (H) for
longer than one rotation of the polygon.
Details:
• Occurs when the PATMOS polygon error determination register
detects that the XSCRDY signal was inactive (H) for longer than one
rotation of the polygon (7 cycles of PMCLK).
• The PATMOS polygon error determination register detects that the
XSCRDY signal was inactive (H) for longer than one rotation of the
polygon, and then refers to SCERR2.
• Polygon motor or polygon motor driver defective
• The interface harness to the polygon motor driver damaged or not
connected correctly.
• Cycle the machine off/on.
• Replace the laser unit.
• Replace the polygon harness.

Advertisement

Chapters

Table of Contents
loading

Table of Contents