Error Name/Error Condition/Major Cause/Solution
Upper Transport Motor Error (D707)
• Motor pulse not detected for a specified time. (The first time: jam
display, the second time: SC)
• The motor speed does not reach the specified value after a specified
time (t1msec) from motor startup.
• Motor defective
• Connecter disconnected
• Overload
• Check motor connection.
• Replace the motor.
• Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
Lower Transport Motor Error (D707)
• Motor pulse not detected for a specified time. (The first time: jam
display, the second time: SC)
• Motor defective
• Connecter disconnected
• Overload
• Check motor connection.
• Replace the motor.
• Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
Pre-stack Tansport Motor Error (D707)
Upper Tray Exit Motor Error (D707)
Shift Tray Exit Motor Error (D707)
Stapler Exit Motor Error (D707)
Service Call 700-780