SC460
SC No.
D135 RTB 48
D135 RTB 116
D137 RTB 64
SC460-00
SC No.
SC465-01
SC465-02
SC465-03
SC465-04
SC465-05
Level
Error Name/Error Condition/Major Cause/Solution
Separation Power Pack Error (Leak)
An interrupt checks the status of the power pack every 10 ms. This SC is
issued if a problem exists with 50 consecutive samplings (500 ms).
Details:
SC issued when the separation power pack output current is leaking.
The IOB checks for SC signals as described above.
• Image transfer power pack AC output is leaking.
Check if the drawer unit is closed correctly using the following procedure.
1. Turn off the machine power and pull out the drawer unit.
D
2. Close the drawer unit completely and turn on the machine power.
3. Make two or three copies and confirm the error message has
disappeared.
Remove the high voltage cable from the output terminal of the separation
power pack and check the following items.
• PWM signal check
If signal is fixed during image transfer, replace the cable or the IOB.
• Separation power pack output check
If output is fixed during image transfer, replace the power pack.
If output is normal during image transfer, replace the high voltage
cable or the quenching needle.
Level
Error Name/Error Condition/Major Cause/Solution
D
PTR motor: Lock: Encoder 1 error
D
PTR motor (K) Lock: Encoder 2 error
D
PTR motor (K) Lock: Encoder 1/2 error
D
PTR motor (K) Lock: Hole error
D
PTR motor (K) Lock: Overload error
Service Call 400-498