5. Troubleshooting
SC No.
SC700-02
1198
Level
Error Name/Error Condition/Major Cause/Solution
Original pick up error (1-pass ADF)
The pick-up motor is turned on but the pick-up home position sensor is not
detecting it.
Details:
The ADF notifies the main machine of the error. The first two occurences
are displayed as jams.
• Pick-up HP sensor output error
D
• Pick-up motor error (does not rotate)
• ARDF main board defective
• Check the connections of the sensor harnesses and motor harnesses.
• Replace the sensor harnesses and motor harnesses.
• Replace the sensor or motor.
• Replace the ARDF main board.