SC No.
Level
SC381-01
D
SC381-02
D
SC381-03
D
SC381-04
D
SC No.
Level
SC382-01
D
SC382-02
D
SC382-03
D
SC382-04
D
Error Name/Error Condition/Major Cause/Solution
Potential sensor output high error (K)
Potential sensor output high error (C)
Potential sensor output high error (M)
Potential sensor output high error (Y)
Vd(700) greater than 800[-V]
Details:
In Vd detection, which is done at the beginning of process control, the
measured potential (Vd) is converted to the potential when -700 V is
applied to the drum (Vd700) and used to check the potential sensor.
Potential sensor dirty (foreign object, such as toner, entering the probe
window) / potential sensor probe connector disconnected / potential
sensor probe defective.
• Use a blower brush to clean the window of the potential sensor
probe, then check the sensor again.
• Disconnect and reconnect the potential sensor probe connector,
then check the sensor again.
• Disconnect and reconnect the harness connecting the potential
sensor board and potential sensor probe, then check the sensor
again.
• If this does not solve the problem, replace the potential sensor
probe.
Error Name/Error Condition/Major Cause/Solution
Potential sensor output low error (K)
Potential sensor output low error (C)
Potential sensor output low error (M)
Potential sensor output low error (Y)
Service Call 300-398