Error Name/Error Condition/Major Cause/Solution
Downstream device communication error (D751)
• Communication with the downstream device has established, but the
device is not responding to the command sent out, even after being
sent three times.
• The port level of the downstream device does not become H level
(break cancel) within specified time.
• Interface cable (downstream device side) connector disconnected
or broken
• Board defective (Buffer pass unit or downstream device)
• Replace the interface cable between buffer pass unit and
downstream device or reconnect the connectors.
• Replace the board (of the buffer pass unit or downstream device).
Error Name/Error Condition/Major Cause/Solution
Buffer pass unit_CTB_+24V_Power supply error
Detected +24V power OFF of the Buffer pass unit PCB: CTB.
• Buffer pass unit PSU defect
• Connecter disconnected
• Harness ground fault/broken
• 24V load (motor/fan) layer short
• PCB defective
• Fuse tripped (PSU, PCB)
• Replace the Buffer pass unit PSU.
• Reconnect the connector.
• Replace the harness.
• Replace the motor/fan.
• Replace the PCB.
Service Call 700-780