SC No.
Level
SC994-00
C
SC No.
Level
SC997-00
D
SC No.
Level
SC998-00
D
Error Name/Error Condition/Major Cause/Solution
Operation error caused by abnormalities that are normally undetectable.
An error occurred because the number of records exceeded the
limit for images managed in the service layer of the firmware.
This can occur if there are too many application screens open
on the operation panel.
Logging only.
Error Name/Error Condition/Major Cause/Solution
Application function selection error
The application selected by the operation panel key operated
abnormally (No response, abnormal ending).
Software bug (mainly the application)
• Check the optional RAM, DIMM, boards required by the
application program.
• Check if the combination of downloaded programs are correct.
Error Name/Error Condition/Major Cause/Solution
Application start error
• No application was registered to system within a specified time after
the main power was turned on.
(No application starts/All applications have been terminated
abnormally)
• Application started but cannot be drawn now for some reason.
• Software bug (mainly the application)
• The optional RAM, DIMM, boards required by the application
program. Are not installed correctly.
• Turn the main power off/on.
• Check the optional RAM, DIMM, boards
• Check the combination of programs
• Replace the controller board.
Service Call 900-998