Ricoh MP C6502SP Field Service Manual page 1205

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

SC No.
Level
SC700-09
D
SC No.
Level
SC701-02
D
Error Name/Error Condition/Major Cause/Solution
Exit motor error (1-pass ADF)
Error signal detected while the motor is driven.
Details:
When encoder channel A (B) error or overload error is detected among
the exit motor error notification registers.
The first two occurences, however, are displayed as jams.
• Motor defective
• Connecter disconnected
• Harness broken
• Overload
• Check the harness connection.
• Replace the encoder harness.
• Replace the motor.
• Replace the board.
• Remove torn paper from the paper path, remove foreign objects
from the drive area, and check for motor/motor bracket
deformation.
Error Name/Error Condition/Major Cause/Solution
Original pick-up motor driver error (1-pass ADF)
Motor driver IC error flag was asserted when a jam occurred.
Details:
The protection mechanism of the motor driver IC detected overcurrent or
overheat and output an error.
Motor driver IC detected an error.
• Check the motor harness connection.
• Check for torn paper on the paper path or foreign objects in the
drive area.
• Replace the motor harness.
• Replace the motor.
• Replace the board.
Service Call 700-780
1203

Advertisement

Chapters

Table of Contents
loading

Table of Contents