5. Troubleshooting
SC No.
SC101-02
SC No.
SC102-00
1028
Level
Error Name/Error Condition/Major Cause/Solution
Lamp Error (LED illumination adjustment)
LED error was detected.
• LED defective
• IDB (LED driver) defective
• Power/signal harness defective
D
• Cycle the machine off/on.
• Reconnect the power/signal harness.
• Replace the LED board.
• Replace the IDB board.
• Replace the SIO board.
• Replace the power/signal harness.
Level
Error Name/Error Condition/Major Cause/Solution
LED Illumination Adjustment Error
The white level peak reached the prescribed threshold when the white
plate was scanned after a specified number of adjustments.
• LED defective
• IDB (LED driver) defective
• SBU defective
• IPU defective
D
• Power/signal harness defective
• Cycle the machine off/on.
• Reconnect the power/signal harness.
• Replace the IDB board.
• Replace the SIO board.
• Replace the SBU board.
• Replace the IPU board.
• Replace the power/signal harness.