Ricoh MP C6502SP Field Service Manual page 1202

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

5. Troubleshooting
SC No.
SC700-05
1200
Level
Error Name/Error Condition/Major Cause/Solution
Pull-out motor error (1-pass ADF)
Error signal detected while the motor is driven.
Details:
When encoder channel A (B) error or overload error is detected among
the pull-out motor error notification registers.
The first two occurences, however, are displayed as jams.
• Motor defective
• Connecter disconnected
D
• Harness broken
• Overload
• Check the harness connection.
• Replace the encoder harness.
• Replace the motor.
• Replace the board.
• Remove torn paper from the paper path, remove foreign objects
from the drive area, and check for motor/motor bracket
deformation.