Ricoh MP C6502SP Field Service Manual page 1119

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

SC No.
Level
SC505-01
B
SC No.
Level
SC505-02
B
Error Name/Error Condition/Major Cause/Solution
LCT Tray Error (Lift Sensor Error): D709
The following status was detected 5 times consecutively: The upper limit
sensor did not become on before pick-up solenoid is on at the start of tray
initialization.
• Pick-up solenoid defective/connecter disconnected
• Upper limit sensor defective/connecter disconnected
• Related harness broken
• PCB defective
• Replace or reconnect the pick-up solenoid.
• Replace or reconnect the lift sensor.
• Replace the corresponding harness.
• Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
LCT Tray Error (Lift Timeout): D709
During Tray initialization, the tray bottom plate was lifted but the upper
limit sensor did not detect it after a specified time (30 seconds).
• Upper limit motor defective/connecter disconnected
• Upper limit sensor defective/connecter disconnected
• Related harness broken
• PCB defective
• Replace or reconnect the lift motor.
• Replace or reconnect the upper limit sensor.
• Replace the corresponding harness.
• Replace the PCB.