5. Troubleshooting
[A]: Rubber rollers x 5
Step 2: Decreasing the fusing temp
Decrease the fusing temp by 1 step (10 °C) in either the IMSS or SP mode.
• Decreasing the fusing temp may cause poor fusing. Make sure to check the results after every
adjustment.
IMSS No.
74
(SP1-984-001 to 100)
SP No.
SP1-984-109 to 254
Troubleshooting for 2-3mm pitch banding
Symptom
Banding (uneven density) in 2-3mm pitch
1416
Description
Fusing Heat Roller Temperature Adjustment (for
each custom paper)
Description
Htg Roller Temp Setting (for each paper type/
thickness)
Range
0 to 200 °C
Range
0 to 200 °C