Ricoh MP C6502SP Field Service Manual page 1169

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

SC No.
Level
SC No.
Level
SC626-04
D
SC626-05
D
SC626-06
D
Error Name/Error Condition/Major Cause/Solution
ASAP communication protocol error
• A BREAK signal was detected at power-on.
• Non-response (100 ms) was detected 3 times consecutively during
normal operation.
• NAK was received 3 times before ACK was received during normal
operation.
• A BREAK signal was detected during normal operation.
• DUB defective
• PFB defective
• Harness between DUB and PFB broken
• Connecter between DUB and PFB disconnected
• Unintended electrical noise
• Replace the DUB.
• Replace the PFB.
• Replace the harness between DUB and PFB.
• Replace the connector between DUB and PFB.
Error Name/Error Condition/Major Cause/Solution
TSB communication error at power-on
TSB communication error during normal operation
TSB BREAK detection during normal operation
Service Call 620-689
1167

Advertisement

Chapters

Table of Contents
loading