Notes on Replacing the Drum Cleaning Unit and Drum Cleaning Blade

Do not replace the drum cleaning unit or the drum cleaning blade at the same time as the following
parts.
• ITB
• ITB Cleaning Unit
• ITB Cleaning Blade
• ITB Lubricant Bar
• ITB Lubricant Blade
After replacing the drum cleaning unit or the drum cleaning blade, cleaning initial setting is performed
automatically. On the other hand, after replacing the above five parts, you need to run SP2-696-001
(Force Apply Lubricant Execute) manually before cleaning initial setting runs. (
"Lubrication after replacement"). This is because, if cleaning initial setting runs automatically before
running SP2-696-001 (Force Apply Lubricant Execute) manually, the ITB cleaning blade will be turned
up
If you need to replace the above five parts at the same time as replacing the drum cleaning unit or the
drum cleaning blade, use the following procedure.
1. Clear the counter of the drum cleaning unit or the drum cleaning blade.
2. Replace the drum cleaning unit or the drum cleaning blade. (The cleaning initial setting
automatically runs)
3. Clear the counters of the above five parts